{"product_id":"75-gpd-ro-membrane","title":"75 GPD RO Membrane","description":"\u003cp\u003e\u003cstrong\u003eYour TDS meter used to read low on the RO faucet. Now the number is creeping toward what comes out of the kitchen tap.\u003c\/strong\u003e That is the clearest sign a reverse osmosis membrane is wearing out, and swapping it brings the system back to the water you bought it for.\u003c\/p\u003e\u003cp\u003eThis 75 GPD thin film composite (TFC) membrane is the optional membrane listed for Crystal Quest Thunder under-sink RO systems, whose standard membrane is 100 GPD. If your system already runs a 75 GPD membrane and you want to keep that rating, this is the matching replacement. It measures 1.75\" x 11.75\" for 2\" x 12\" residential membrane housings and reduces dissolved contaminants, including lead, mercury, cadmium, trivalent chromium, fluoride, nitrates, sodium and radium.\u003c\/p\u003e\u003ch3\u003eAt a glance\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLike-for-like replacement\u003c\/strong\u003e for a 75 GPD membrane in a Thunder under-sink RO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrings RO-water TDS back down\u003c\/strong\u003e when the old membrane has worn out\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard residential size,\u003c\/strong\u003e 1.75\" x 11.75\", part CQE-RC-04063\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 99% reduction\u003c\/strong\u003e of dissolved solids (TDS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 to 3 years of service,\u003c\/strong\u003e depending on feed water quality, system configuration and usage\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhat you are looking at\u003c\/h3\u003e\u003cp\u003eThe membrane is a spiral wound roll. Flat sheets of TFC membrane, separated by polyethylene netting, wrap around a perforated center tube and sit inside polyolefin wraps. Polypropylene end caps and Buna-N gaskets seal it in the housing, and the two small O-rings mark the end that goes in first.\u003c\/p\u003e\u003ch3\u003eHow a 75 GPD RO membrane works\u003c\/h3\u003e\u003ch4\u003eWhat happens at the membrane surface\u003c\/h4\u003e\u003cp\u003eThe working surface of a TFC membrane is a polyamide film far thinner than the support layers beneath it. Under pressure, water molecules work their way through that film. Dissolved salts and metals, carried in water as charged ions, are held back and swept away by the water flowing across the surface.\u003c\/p\u003e\u003ch4\u003eTwo streams leave the membrane\u003c\/h4\u003e\u003cp\u003ePurified water (permeate) collects in the center tube and fills your storage tank. Everything the membrane rejected leaves in the concentrate stream to the drain, and that steady flow is what keeps the surface from clogging. Crystal Quest RO systems send 1 gallon to drain for every 1 to 3 gallons of purified water.\u003c\/p\u003e\u003ch4\u003eYour 75 GPD in a real kitchen\u003c\/h4\u003e\u003cp\u003eThe rating is the membrane's daily production at its standard test conditions. In a home, output moves with the seasons and the plumbing. Cold winter water moves through the membrane more slowly, low water pressure gives it less push, and high-TDS water pushes back. Pressure matters for purity too: water pressure affects both how much water the membrane makes and how well it rejects dissolved solids.\u003c\/p\u003e\u003ch4\u003eGases and small molecules\u003c\/h4\u003e\u003cp\u003eDissolved gases and some very small uncharged molecules pass a membrane more easily than salts do. That is why the carbon stages before the membrane and the polishing stage after it are part of every Thunder system.\u003c\/p\u003e\u003ch4\u003eWhat shortens membrane life\u003c\/h4\u003e\u003cp\u003eChlorine attacks the polyamide film and the damage does not reverse, so the carbon pre-filters must stay current. Hard water can deposit a crystallized layer of scale on the surface, and very hard water should be softened ahead of RO. A system left unused for weeks lets water sit stale in the housings.\u003c\/p\u003e\n\u003ch3\u003eWhat it reduces\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003ePrimary target:\u003c\/strong\u003e total dissolved solids, including lead, mercury, cadmium, trivalent chromium, fluoride, nitrates, sodium and radium.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHandled by the system's other stages:\u003c\/strong\u003e chlorine and chloramine, taste and odor, and UV treatment on Thunder 3000 and 4000 models.\u003c\/p\u003e\u003ch3\u003eWhy Crystal Quest\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMade for Crystal Quest systems:\u003c\/strong\u003e the 75 GPD membrane listed for Thunder, with its own part number, so you replace like with like.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear guidance on ratings:\u003c\/strong\u003e 100 GPD is the Thunder standard and 75 GPD remains available; we will tell you which suits your system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver 1,000,000 people served since 1994.\u003c\/strong\u003e Crystal Quest builds under ISO 9001 quality management, has made water filtration in the USA for over 30 years and offers lifetime support by phone, email or chat.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhere it fits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrystal Quest Thunder under-sink RO systems\u003c\/strong\u003e running the optional 75 GPD membrane. The standard Thunder membrane is the \u003ca href=\"https:\/\/crystalquest.com\/products\/100-gpd-reverse-osmosis-membrane\"\u003e100 GPD membrane\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e 2\" x 12\" residential membrane housing; membrane size 1.75\" x 11.75\".\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eMembranes are not returnable, so check the rating and part number on your current membrane, or ask Crystal Quest, before you order.\u003c\/p\u003e\u003ch3\u003eCommon questions\u003c\/h3\u003e\u003cdiv class=\"cq-product-faq\"\u003e\n\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eIs 75 GPD the standard Thunder membrane?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eNo. Every Thunder under-sink RO system comes standard with the 100 GPD membrane. The 75 GPD membrane is listed as an optional replacement and remains available.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eIs a higher GPD rating always better?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eGPD is the membrane's rated daily production, not faucet flow. Real output changes with water pressure, temperature and TDS. Use the rating your system lists, and ask Crystal Quest before changing it.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eHow do I know my 75 GPD RO membrane needs replacing?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eCompare tap-water and RO-water TDS. If the RO reading keeps rising, or production stays low with fresh pre-filters and normal pressure, the membrane is due. Most last 2 to 3 years.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eDoes the 75 GPD membrane fit any 2\" x 12\" housing?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eIt is a 1.75\" x 11.75\" residential membrane listed for Crystal Quest Thunder systems. For any other system, check its manual or ask Crystal Quest before ordering.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eWhat ruins an RO membrane early?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eChlorine reaching the membrane through exhausted carbon pre-filters, scale from very hard water, and long periods without use.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eHow do I replace the membrane?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eTurn off the water, unscrew the membrane housing cap, pull out the old membrane and push the new one in, end with the two small O-rings first, until it is fully seated. Then reconnect, check for leaks and flush as your system manual directs.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n###\n\u003ch3\u003eMembrane specifications\u003c\/h3\u003e\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eMembrane type\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003eThin-film composite (TFC) reverse osmosis membrane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eProduction rating\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003e75 GPD (gallons per day)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003ePart number\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003eCQE-RC-04063\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eMembrane size\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003e1.75\" x 11.75\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eHousing format\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003e2\" x 12\" residential membrane housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eListed replacement for\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003eCrystal Quest Thunder under-sink RO systems (optional membrane; the standard is 100 GPD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eConstruction\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003ePolypropylene end caps, polyolefin inner and outer wraps, polyethylene netting, Buna-N gasket end caps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eOperating pressure\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003e20 to 60 psi (1.4 to 4.1 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003e40°F to 90°F (4°C to 32°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eSalt rejection\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003eUp to 99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eChlorine\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003eRemove ahead of the membrane with carbon pre-filtration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eDrain water (Crystal Quest RO systems)\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003e1 gallon to drain for every 1 to 3 gallons of purified water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\"\u003eService life\u003c\/td\u003e\n\u003ctd valign=\"middle\"\u003e2 to 3 years*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e*Service life is an estimate. Actual life depends on feed water quality, system configuration and usage.\u003c\/p\u003e\n","brand":"Crystal Quest Water Filters","offers":[{"title":"Single","offer_id":67902177870057,"sku":"CQE-RC-04063","price":44.0,"currency_code":"USD","in_stock":true},{"title":"Pack of 2","offer_id":67902177902825,"sku":"CQE-RC-04063-2PK","price":88.0,"currency_code":"USD","in_stock":true},{"title":"Pack of 4","offer_id":67902177935593,"sku":"CQE-RC-04063-4PK","price":176.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0814\/4512\/6377\/files\/75-gpd-ro-membrane-crystal-quest-water-filter-cartridges-1263463656.webp?v=1794168561","url":"https:\/\/clearwaterworld.com\/products\/75-gpd-ro-membrane","provider":"Clearwater World","version":"1.0","type":"link"}